This chapter is concerned with testing and configuring your tape drive to make sure that it will work properly with Bacula using the btape program.
In general, you should follow the following steps to get your tape drive to work with Bacula. Start with a tape mounted in your drive. If you have an autochanger, load a tape into the drive. We use /dev/nst0 as the tape drive name, you will need to adapt it according to your system.
Do not proceed to the next item until you have succeeded with the previous one.
mt -f /dev/nst0 rewind tar cvf /dev/nst0 . mt -f /dev/nst0 rewind tar tvf /dev/nst0
./btape -c bacula-sd.conf /dev/nst0 test
It isn't necessary to run the autochanger part of the test at this time, but do not go past this point until the basic test succeeds. If you do have an autochanger, please be sure to read the Autochanger chapter chapter of the Bacula Enterprise Main manual.
restore select all done yes
Do a diff on the restored directory to ensure it is identical to the original directory. If you are going to backup multiple different systems (Linux, Windows, Mac, Solaris, FreeBSD, ...), be sure you test the restore on each system type.
./btape -c bacula-sd.conf /dev/nst0 auto
Adjust your autochanger as necessary to ensure that it works correctly. See the Autochanger chapter of this manual for a complete discussion of testing your autochanger.
Feb 14 17:29:55 epohost kernel: (scsi0:A:2:0): No or incomplete CDB sent to device. Feb 14 17:29:55 epohost kernel: scsi0: Issued Channel A Bus Reset. 1 SCBs aborted
If you have reached this point, you stand a good chance of having everything work. If you get into trouble at any point, carefully read the documentation given below. If you cannot get past some point, ask the bacula-users email list, but specify which of the steps you have successfully completed. In particular, you may want to look at the Tips for Resolving Problems section below.
With version 2.6 of the Linux kernel, if there is no tape in the drive, the OS will wait two minutes (default) and then return a failure, and consequently, Bacula version 1.36 and below will fail the job. This is important to keep in mind, because if you use an option such as Offline on Unmount = yes, there will be a point when there is no tape in the drive, and if another job starts or if Bacula asks the operator to mount a tape, when Bacula attempts to open the drive (about a 20 minute delay), it will fail and Bacula will fail the job.
In version 1.38.x, the Bacula code partially gets around this problem - at least in the initial open of the drive. However, functions like Polling the drive do not work correctly if there is no tape in the drive. Providing you do not use Offline on Unmount = yes, you should not experience job failures as mentioned above. If you do experience such failures, you can also increase the Maximum Open Wait time interval, which will give you more time to mount the next tape before the job is failed.
Starting with version 1.27, each of the tape utility programs including the btape program requires a valid Storage daemon configuration file (actually, the only part of the configuration file that btape needs is the Device resource definitions). This permits btape to find the configuration parameters for your archive device (generally a tape drive). Without those parameters, the testing and utility programs do not know how to properly read and write your drive. By default, they use bacula-sd.conf in the current directory, but you may specify a different configuration file using the -c option.
btape device-name where the Volume can be found. In the case of a tape, this is the physical device name such as /dev/nst0 or /dev/rmt/0ubn depending on your system that you specify on the Archive Device directive. For the program to work, it must find the identical name in the Device resource of the configuration file. If the name is not found in the list of physical names, the utility program will compare the name you entered to the Device names (rather than the Archive device names).
When specifying a tape device, it is preferable that the “non-rewind” variant of the device file name be given. In addition, on systems such as Sun, which have multiple tape access methods, you must be sure to specify to use Berkeley I/O conventions with the device. The b in the Solaris (Sun) archive specification /dev/rmt/0mbn is what is needed in this case. Bacula does not support SysV tape drive behavior.
See below for specifying Volume names.
If you are attempting to read or write an archive file rather than a tape, the device-name should be the full path to the archive location including the filename. The filename (last part of the specification) will be stripped and used as the Volume name, and the path (first part before the filename) must have the same entry in the configuration file. So, the path is equivalent to the archive device name, and the filename is equivalent to the volume name.
This program permits a number of elementary tape operations via a tty command interface. The test command, described below, can be very useful for testing tape drive compatibility problems. Aside from initial testing of tape drive compatibility with Bacula, btape will be mostly used by developers writing new tape drivers.
btape can be dangerous to use with existing Bacula tapes because it will relabel a tape or write on the tape if so requested regardless of whether or not the tape contains valuable data, so please be careful and use it only on blank tapes.
To work properly, btape needs to read the Storage daemon's configuration file. As a default, it will look for bacula-sd.conf in the current directory. If your configuration file is elsewhere, please use the -c option to specify where.
The physical device name or the Device resource name must be specified on the command line, and this same device name must be present in the Storage daemon's configuration file read by btape
Usage: btape [options] device_name -b <file> specify bootstrap file -c <file> set configuration file to file -d <nn> set debug level to nn -p proceed inspite of I/O errors -s turn off signals -v be verbose -? print this message.
An important reason for this program is to ensure that a Storage daemon configuration file is defined so that Bacula will correctly read and write tapes.
It is highly recommended that you run the test command before running your first Bacula job to ensure that the parameters you have defined for your storage device (tape drive) will permit Bacula to function properly. You only need to mount a blank tape, enter the command, and the output should be reasonably self explanatory. For example:
(ensure that Bacula is not running) ./btape -c /usr/bin/bacula/bacula-sd.conf /dev/nst0
The output will be:
Tape block granularity is 1024 bytes. btape: btape.c:376 Using device: /dev/nst0 *
Enter the test command:
test
The output produced should be something similar to the following: I've cut the listing short because it is frequently updated to have new tests.
=== Append files test === This test is essential to Bacula. I'm going to write one record in file 0, two records in file 1, and three records in file 2 btape: btape.c:387 Rewound /dev/nst0 btape: btape.c:855 Wrote one record of 64412 bytes. btape: btape.c:857 Wrote block to device. btape: btape.c:410 Wrote EOF to /dev/nst0 btape: btape.c:855 Wrote one record of 64412 bytes. btape: btape.c:857 Wrote block to device. btape: btape.c:855 Wrote one record of 64412 bytes. btape: btape.c:857 Wrote block to device. btape: btape.c:410 Wrote EOF to /dev/nst0 btape: btape.c:855 Wrote one record of 64412 bytes. btape: btape.c:857 Wrote block to device. btape: btape.c:855 Wrote one record of 64412 bytes. btape: btape.c:857 Wrote block to device. btape: btape.c:855 Wrote one record of 64412 bytes. btape: btape.c:857 Wrote block to device. btape: btape.c:410 Wrote EOF to /dev/nst0 btape: btape.c:387 Rewound /dev/nst0 btape: btape.c:693 Now moving to end of media. btape: btape.c:427 Moved to end of media We should be in file 3. I am at file 3. This is correct! Now the important part, I am going to attempt to append to the tape. ... === End Append files test ===
If you do not successfully complete the above test, please resolve the problem(s) before attempting to use Bacula. Depending on your tape drive, the test may recommend that you add certain records to your configuration. We strongly recommend that you do so and then re-run the above test to insure it works the first time.
Some of the suggestions it provides for resolving the problems may or may not be useful. If at all possible avoid using fixed blocking. If the test suddenly starts to print a long series of:
Got EOF on tape. Got EOF on tape. ...
then almost certainly, you are running your drive in fixed block mode rather than variable block mode. See below for more help of resolving fix versus variable block problems.
It is also possible that you have your drive set in SysV tape drive mode. The drive must use BSD tape conventions. See the section above on setting your Archive device correctly.
For FreeBSD users, please see the notes below for doing further testing of your tape drive.
To determine the best configuration of your tape drive, you can run the speed command available in the btape program.
This command can have the following arguments:
*speed file_size=3 skip_raw btape.c:1078 Test with zero data and bacula block structure. btape.c:956 Begin writing 3 files of 3.221 GB with blocks of 129024 bytes. ++++++++++++++++++++++++++++++++++++++++++ btape.c:604 Wrote 1 EOF to "Drive-0" (/dev/nst0) btape.c:406 Volume bytes=3.221 GB. Write rate = 44.128 MB/s ... btape.c:383 Total Volume bytes=9.664 GB. Total Write rate = 43.531 MB/s btape.c:1090 Test with random data, should give the minimum throughput. btape.c:956 Begin writing 3 files of 3.221 GB with blocks of 129024 bytes. +++++++++++++++++++++++++++++++++++++++++++ btape.c:604 Wrote 1 EOF to "Drive-0" (/dev/nst0) btape.c:406 Volume bytes=3.221 GB. Write rate = 7.271 MB/s +++++++++++++++++++++++++++++++++++++++++++ ... btape.c:383 Total Volume bytes=9.664 GB. Total Write rate = 7.365 MB/s
When using compression, the random test will give your the minimum throughput of your drive . The test using constant string will give you the maximum speed of your hardware chain. (cpu, memory, scsi card, cable, drive, tape).
You can change the block size in the Storage Daemon configuration file.
You can find out what SCSI devices you have by doing:
lsscsi
Typical output is:
[0:0:0:0] disk ATA ST3160812AS 3.AD /dev/sda [2:0:4:0] tape HP Ultrium 2-SCSI F6CH /dev/st0 [2:0:5:0] tape HP Ultrium 2-SCSI F6CH /dev/st1 [2:0:6:0] mediumx OVERLAND LXB 0107 - [2:0:9:0] tape HP Ultrium 1-SCSI E50H /dev/st2 [2:0:10:0] mediumx OVERLAND LXB 0107 -
There are two drives in one autochanger: /dev/st0 and /dev/st1 and a third tape drive at /dev/st2. For using them with Bacula, one would normally reference them as /dev/nst0 ... /dev/nst2. Not also, there are two different autochangers identified as “mediumx OVERLAND LXB”. They can be addressed via their /dev/sgN designation, which can be obtained by counting from the beginning as 0 to each changer. In the above case, the two changers are located on /dev/sg3 and /dev/sg5. The one at /dev/sg3, controls drives /dev/nst0 and /dev/nst1; and the one at /dev/sg5 controles drive /dev/nst2.
If you do not have the lsscsi command, you can obtain the same information as follows:
cat /proc/scsi/scsi
For the above example with the three drives and two autochangers, I get:
Attached devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: ATA Model: ST3160812AS Rev: 3.AD Type: Direct-Access ANSI SCSI revision: 05 Host: scsi2 Channel: 00 Id: 04 Lun: 00 Vendor: HP Model: Ultrium 2-SCSI Rev: F6CH Type: Sequential-Access ANSI SCSI revision: 03 Host: scsi2 Channel: 00 Id: 05 Lun: 00 Vendor: HP Model: Ultrium 2-SCSI Rev: F6CH Type: Sequential-Access ANSI SCSI revision: 03 Host: scsi2 Channel: 00 Id: 06 Lun: 00 Vendor: OVERLAND Model: LXB Rev: 0107 Type: Medium Changer ANSI SCSI revision: 02 Host: scsi2 Channel: 00 Id: 09 Lun: 00 Vendor: HP Model: Ultrium 1-SCSI Rev: E50H Type: Sequential-Access ANSI SCSI revision: 03 Host: scsi2 Channel: 00 Id: 10 Lun: 00 Vendor: OVERLAND Model: LXB Rev: 0107 Type: Medium Changer ANSI SCSI revision: 02
As an additional example, I get the following (on a different machine from the above example):
Attached devices: Host: scsi2 Channel: 00 Id: 01 Lun: 00 Vendor: HP Model: C5713A Rev: H107 Type: Sequential-Access ANSI SCSI revision: 02 Host: scsi2 Channel: 00 Id: 04 Lun: 00 Vendor: SONY Model: SDT-10000 Rev: 0110 Type: Sequential-Access ANSI SCSI revision: 02
The above represents first an autochanger and second a simple tape drive. The HP changer (the first entry) uses the same SCSI channel for data and for control, so in Bacula, you would use:
Archive Device = /dev/nst0 Changer Device = /dev/sg0
If you want to remove the SDT-10000 device, you can do so as root with:
echo "scsi remove-single-device 2 0 4 0">/proc/scsi/scsi
and you can put add it back with:
echo "scsi add-single-device 2 0 4 0">/proc/scsi/scsi
where the 2 0 4 0 are the Host, Channel, Id, and Lun as seen on the output from cat /proc/scsi/scsi. Note, the Channel must be specified as numeric.
Below is a slightly more complicated output, which is a single autochanger with two drives, and which operates the changer on a different channel from from the drives:
Attached devices: Host: scsi0 Channel: 00 Id: 00 Lun: 00 Vendor: ATA Model: WDC WD1600JD-75H Rev: 08.0 Type: Direct-Access ANSI SCSI revision: 05 Host: scsi2 Channel: 00 Id: 04 Lun: 00 Vendor: HP Model: Ultrium 2-SCSI Rev: F6CH Type: Sequential-Access ANSI SCSI revision: 03 Host: scsi2 Channel: 00 Id: 05 Lun: 00 Vendor: HP Model: Ultrium 2-SCSI Rev: F6CH Type: Sequential-Access ANSI SCSI revision: 03 Host: scsi2 Channel: 00 Id: 06 Lun: 00 Vendor: OVERLAND Model: LXB Rev: 0106 Type: Medium Changer ANSI SCSI revision: 02
The above tape drives are accessed on /dev/nst0 and /dev/nst1, while the control channel for those two drives is /dev/sg3.
If you are getting error messages such as:
Volume data error at 0:1! Wanted block-id: "BB02", got "". Buffer discarded
It is very likely that Bacula has tried to do block positioning and ended up at an invalid block. This can happen if your tape drive is in fixed block mode while Bacula's default is variable blocks. Note that in such cases, Bacula is perfectly able to write to your Volumes (tapes), but cannot position to read them.
There are two possible solutions.
mt -f /dev/nst0 defblksize 0
or whatever is appropriate on your system. Note, if you are running a Linux system, and the above command does not work, it is most likely because you have not loaded the appropriate mt package, which is often called mt_st, but may differ according to your distribution.
Block Positioning = no
to the Device resource. This is not the recommended procedure because it can enormously slow down recovery of files, but it may help where all else fails. This directive is available in version 1.35.5 or later (and not yet tested).
If you are getting error messages such as:
Volume data error at 0:0! Block checksum mismatch in block=0 len=32625 calc=345678 blk=123456
You are getting tape read errors, and this is most likely due to one of the following things:
If you get an error message such as:
dev open failed: dev.c:265 stored: unable to open device /dev/nst0:> ERR=No such device or address
the first time you run a job, it is most likely due to the fact that you specified the incorrect device name on your Archive Device.
If Bacula works fine with your drive, then all off a sudden you get error messages similar to the one shown above, it is quite possible that your driver module is being removed because the kernel deems it idle. This is done via crontab with the use of rmmod -a. To fix the problem, you can remove this entry from crontab, or you can manually modprob your driver module (or add it to the local startup script). Thanks to Alan Brown for this tip.
Sometimes the tape handler gets confused. This can happen if your tape drive door is locked (Bacula locks it when writing a tape), and Bacula crashes or some other problem occurs. After this kind of a problem, the kernel driver will not recognize that a tape is loaded and you may see messages such as:
19-Sep 16:39 groschat-sd JobId 16072: Warning: mount.c:219 Open of tape device "LTO4-Drive" (/dev/tape/by-id/scsi-3500143801403cf22-nst) Volume "AAJ372" failed: ERR=tape_dev.c:162 Unable to open device "LTO4-Drive" (/dev/tape/by-id/scsi-3500143801403cf22-nst): ERR=No medium found 19-Sep 16:39 groschat-sd JobId 16072: Please mount append Volume "AAJ372" or label a new one for: Job: Rufus.2016-09-19_16.34.22_03 Storage: "LTO4-Drive" (/dev/tape/by-id/scsi-3500143801403cf22-nst) Pool: Default Media type: LTO-4
in that case, the best thing to do is unload the tape by hand with:
(stop Bacula) mtx -f /dev/sgx unload (restart Bacula)
where you replace /dev/sgx by your scsi control device name.
When Bacula moves to the end of the medium, it normally uses the ioctl(MTEOM) function. Then Bacula uses the ioctl(MTIOCGET) function to retrieve the current file position from the mt_fileno field. Some SCSI tape drivers will use a fast means of seeking to the end of the medium and in doing so, they will not know the current file position and hence return a -1. As a consequence, if you get “This is NOT correct!” in the positioning tests, this may be the cause. You must correct this condition in order for Bacula to work.
There are two possible solutions to the above problem of incorrect file number:
Hardware End of File = no
This will cause Bacula to use the MTFSF request to seek to the end of the medium, and Bacula will keep track of the file number itself.
Bacula's preferred method of working with tape drives (sequential devices) is to run in variable block mode, and this is what is set by default. You should first ensure that your tape drive is set for variable block mode (see below).
If your tape drive is in fixed block mode and you have told Bacula to use different fixed block sizes or variable block sizes (default), you will get errors when Bacula attempts to forward space to the correct block (the kernel driver's idea of tape blocks will not correspond to Bacula's).
All modern tape drives support variable tape blocks, but some older drives (in particular the QIC drives) as well as the ATAPI ide-scsi driver run only in fixed block mode. The Travan tape drives also apparently must run in fixed block mode (to be confirmed).
Even in variable block mode, with the exception of the first record on the second or subsequent volume of a multi-volume backup, Bacula will write blocks of a fixed size. However, in reading a tape, Bacula will assume that for each read request, exactly one block from the tape will be transferred. This the most common way that tape drives work and is well supported by Bacula.
Drives that run in fixed block mode can cause serious problems for Bacula if the drive's block size does not correspond exactly to Bacula's block size. In fixed block size mode, drivers may transmit a partial block or multiple blocks for a single read request. From Bacula's point of view, this destroys the concept of tape blocks. It is much better to run in variable block mode, and almost all modern drives (the OnStream is an exception) run in variable block mode. In order for Bacula to run in fixed block mode, you must include the following records in the Storage daemon's Device resource definition:
Minimum Block Size = nnn Maximum Block Size = nnn
where nnn must be the same for both records and must be identical to the driver's fixed block size.
We recommend that you avoid this configuration if at all possible by using variable block sizes.
If you must run with fixed size blocks, make sure they are not 512 bytes. This is too small and the overhead that Bacula has with each record will become excessive. If at all possible set any fixed block size to something like 64,512 bytes or possibly 32,768 if 64,512 is too large for your drive. See below for the details on checking and setting the default drive block size.
To recover files from tapes written in fixed block mode, see below.
If you have a modern SCSI tape drive and you are having problems with the test command as noted above, it may be that some program has set one or more of your SCSI driver's options to non-default values. For example, if your driver is set to work in SysV manner, Bacula will not work correctly because it expects BSD behavior. To reset your tape drive to the default values, you can try the following, but ONLY if you have a SCSI tape drive on a Linux system:
become super user mt -f /dev/nst0 rewind mt -f /dev/nst0 stoptions buffer-writes async-writes read-ahead
The above commands will clear all options and then set those specified. None of the specified options are required by Bacula, but a number of other options such as SysV behavior must not be set. Bacula does not support SysV tape behavior. On systems other than Linux, you will need to consult your mt man pages or documentation to figure out how to do the same thing. This should not really be necessary though - for example, on both Linux and Solaris systems, the default tape driver options are compatible with Bacula. On Solaris systems, you must take care to specify the correct device name on the Archive device directive. See above for more details.
You may also want to ensure that no prior program has set the default block size, as happened to one user, by explicitly turning it off with:
mt -f /dev/nst0 defblksize 0
If you are running a Linux system, and the above command does not work, it is most likely because you have not loaded the appropriate mt package, which is often called mt_st, but may differ according to your distribution.
If you would like to know what options you have set before making any of the changes noted above, you can now view them on Linux systems, thanks to a tip provided by Willem Riede. Do the following:
become super user mt -f /dev/nst0 stsetoptions 0 grep st0 /var/log/messages
and you will get output that looks something like the following:
kernel: st0: Mode 0 options: buffer writes: 1, async writes: 1, read ahead: 1 kernel: st0: can bsr: 0, two FMs: 0, fast mteom: 0, auto lock: 0, kernel: st0: defs for wr: 0, no block limits: 0, partitions: 0, s2 log: 0 kernel: st0: sysv: 0 nowait: 0
Note, I have chopped off the beginning of the line with the date and machine name for presentation purposes.
Some people find that the above settings only last until the next reboot, so please check this otherwise you may have unexpected problems.
Beginning with Bacula version 1.35.8, if Bacula detects that you are running in variable block mode, it will attempt to set your drive appropriately. All OSes permit setting variable block mode, but some OSes do not permit setting the other modes that Bacula needs to function properly.
You should be able to verify the tape compression status with sysfs on Linux.
cat /sys/class/scsi_tape/nst0/default_compression
You can, turn it on by using (on Linux):
become super user mt -f /dev/nst0 defcompression 1
and of course, if you use a zero instead of the one at the end, you will turn it off.
If you have built the mtx program in the depkgs package, you can use tapeinfo to get quite a bit of information about your tape drive even if it is not an autochanger. This program is called using the SCSI control device. On Linux for tape drive /dev/nst0, this is usually /dev/sg0, while on FreeBSD for /dev/nsa0, the control device is often /dev/pass2. For example on my DDS-4 drive (/dev/nst0), I get the following:
tapeinfo -f /dev/sg0 Product Type: Tape Drive Vendor ID: 'HP ' Product ID: 'C5713A ' Revision: 'H107' Attached Changer: No MinBlock:1 MaxBlock:16777215 SCSI ID: 5 SCSI LUN: 0 Ready: yes BufferedMode: yes Medium Type: Not Loaded Density Code: 0x26 BlockSize: 0
where the DataCompEnabled: yes means that tape hardware compression is turned on. You can turn it on and off (yes|no) by using the mt commands given above. Also, this output will tell you if the BlockSize is non-zero and hence set for a particular block size. Bacula is not likely to work in such a situation because it will normally attempt to write blocks of 64,512 bytes, except the last block of the job which will generally be shorter. The first thing to try is setting the default block size to zero using the mt -f /dev/nst0 defblksize 0 command as shown above. On FreeBSD, this would be something like: mt -f /dev/nsa0 blocksize 0.
On some operating systems with some tape drives, the amount of data that can be written to the tape and whether or not compression is enabled is determined by the density usually the mt -f /dev/nst0 setdensity xxx command. Often mt -f /dev/nst0 status will print out the current density code that is used with the drive. Most systems, but unfortunately not all, set the density to the maximum by default. On some systems, you can also get a list of all available density codes with: mt -f /dev/nst0 densities or a similar mt command. Note, for DLT and SDLT devices, no-compression versus compression is very often controlled by the density code. On FreeBSD systems, the compression mode is set using mt -f /dev/nsa0 comp xxx where xxx is the mode you want. In general, see man mt for the options available on your system.
Note, some of the above mt commands may not be persistent depending on your system configuration. That is they may be reset if a program other than Bacula uses the drive or, as is frequently the case, on reboot of your system.
If your tape drive requires fixed block sizes (very unusual), you can use the following records:
Minimum Block Size = nnn Maximum Block Size = nnn
in your Storage daemon's Device resource to force Bacula to write fixed size blocks (where you sent nnn to be the same for both of the above records). This should be done only if your drive does not support variable block sizes, or you have some other strong reasons for using fixed block sizes. As mentioned above, a small fixed block size of 512 or 1024 bytes will be very inefficient. Try to set any fixed block size to something like 64,512 bytes or larger if your drive will support it.
Also, note that the Medium Type field of the output of tapeinfo reports Not Loaded, which is not correct. As a consequence, you should ignore that field as well as the Attached Changer field.
To recover files from tapes written in fixed block mode, see below.
On most FreeBSD systems such as 4.9 and most tape drives, Bacula should run with:
mt -f /dev/nsa0 seteotmodel 2 mt -f /dev/nsa0 blocksize 0 mt -f /dev/nsa0 comp enable
You might want to put those commands in a startup script to make sure your tape driver is properly initialized before running Bacula, because depending on your system configuration, these modes may be reset if a program other than Bacula uses the drive or when your system is rebooted.
Then according to what the btape test command returns, you will probably need to set the following (see below for an alternative):
Hardware End of Medium = no BSF at EOM = yes Backward Space Record = no Backward Space File = no Fast Forward Space File = no TWO EOF = yes
Then be sure to run some append tests with Bacula where you start and stop Bacula between appending to the tape, or use btape version 1.35.1 or greater, which includes simulation of stopping/restarting Bacula.
Please see the file platforms/freebsd/pthreads-fix.txt in the main Bacula directory concerning important information concerning compatibility of Bacula and your system. A much more optimal Device configuration is shown below, but does not work with all tape drives. Please test carefully before putting either into production.
Note, for FreeBSD 4.10-RELEASE, using a Sony TSL11000 L100 DDS4 with an autochanger set to variable block size and DCLZ compression, Brian McDonald reports that to get Bacula to append correctly between Bacula executions, the correct values to use are:
mt -f /dev/nsa0 seteotmodel 1 mt -f /dev/nsa0 blocksize 0 mt -f /dev/nsa0 comp enable
and
Hardware End of Medium = no BSF at EOM = no Backward Space Record = no Backward Space File = no Fast Forward Space File = yes TWO EOF = no
This has been confirmed by several other people using different hardware. This configuration is the preferred one because it uses one EOF and no backspacing at the end of the tape, which works much more efficiently and reliably with modern tape drives.
Finally, here is a Device configuration that Danny Butroyd reports to work correctly with the Overland Powerloader tape library using LT0-2 and FreeBSD 5.4-Stable:
# Overland Powerloader LT02 - 17 slots single drive Device { Name = Powerloader Media Type = LT0-2 Archive Device = /dev/nsa0 AutomaticMount = yes; AlwaysOpen = yes; RemovableMedia = yes; RandomAccess = no; Changer Command = "/opt/bacula/scripts/mtx-changer %c %o %S %a %d" Changer Device = /dev/pass2 AutoChanger = yes Alert Command = "sh -c 'tapeinfo -f %c |grep TapeAlert|cat'" # FreeBSD Specific Settings Offline On Unmount = no Hardware End of Medium = no BSF at EOM = yes Backward Space Record = no Fast Forward Space File = no TWO EOF = yes }
The following Device resource works fine with Dell PowerVault 110T and 120T devices on both FreeBSD 5.3 and on NetBSD 3.0. It also works with Sony AIT-2 drives on FreeBSD.
Device { ... # FreeBSD/NetBSD Specific Settings Hardware End of Medium = no BSF at EOM = yes Backward Space Record = no Fast Forward Space File = yes TWO EOF = yes }
On FreeBSD version 6.0, it is reported that you can even set Backward Space Record = yes.
On FreeBSD, you can do a camcontrol devlist as root to determine what drives and autochangers you have. For example,
undef# camcontrol devlist at scbus0 target 2 lun 0 (pass0,sa0) at scbus0 target 4 lun 0 (pass1,sa1) at scbus0 target 4 lun 1 (pass2)
from the above, you can determine that there is a tape drive on /dev/sa0 and another on /dev/sa1 in addition since there is a second line for the drive on /dev/sa1, you know can assume that it is the control device for the autochanger (i.e. /dev/pass2). It is also the control device name to use when invoking the tapeinfo program. E.g.
tapeinfo -f /dev/pass2
Bacula version 1.33 (not 1.32x) is now working and ready for testing with the OnStream kernel osst driver version 0.9.14 or above. Osst is available from: sourceforge.net/projects/osst.
To make Bacula work you must first load the new driver then, as root, do:
mt -f /dev/nosst0 defblksize 32768
Also you must add the following to your Device resource in your Storage daemon's conf file:
Minimum Block Size = 32768 Maximum Block Size = 32768
Here is a Device specification provided by Michel Meyers that is known to work:
Device { Name = "Onstream DI-30" Media Type = "ADR-30" Archive Device = /dev/nosst0 Minimum Block Size = 32768 Maximum Block Size = 32768 Hardware End of Medium = yes BSF at EOM = no Backward Space File = yes Fast Forward Space File = yes Two EOF = no AutomaticMount = yes AlwaysOpen = yes Removable Media = yes }
To active, check, or disable the hardware compression feature on an EXB-8900, use the exabyte MammothTool. You can get it here: www.exabyte.com/support/online/downloads/index.cfm. There is a Solaris version of this tool. With option -C 0 or 1 you can disable or activate compression. Start this tool without any options for a small reference.
Because there are often problems with certain tape drives or systems when end of tape conditions occur, btape has a special command fill that causes it to write random data to a tape until the tape fills. It then writes at least one more Bacula block to a second tape. Finally, it reads back both tapes to ensure that the data has been written in a way that Bacula can recover it. Note, there is also a single tape option as noted below, which you should use rather than the two tape test. See below for more details.
This can be an extremely time consuming process (here it is about 6 hours) to fill a full tape. Note, that btape writes random data to the tape when it is filling it. This has two consequences:
To begin this test, you enter the fill command and follow the instructions. There are two options: the simple single tape option and the multiple tape option. Please use only the simple single tape option because the multiple tape option still doesn't work totally correctly. If the single tape option does not succeed, you should correct the problem before using Bacula.
If you have been previously running your tape drive in fixed block mode (default 512) and Bacula with variable blocks (default), then in version 1.32f-x and 1.34 and above, Bacula will fail to recover files because it does block spacing, and because the block sizes don't agree between your tape drive and Bacula it will not work.
The long term solution is to run your drive in variable block mode as described above. However, if you have written tapes using fixed block sizes, this can be a bit of a pain. The solution to the problem is: while you are doing a restore command using a tape written in fixed block size, ensure that your drive is set to the fixed block size used while the tape was written. Then when doing the restore command in the Console program, do not answer the prompt yes/mod/no. Instead, edit the bootstrap file (the location is listed in the prompt) using any ASCII editor. Remove all VolBlock lines in the file. When the file is re-written, answer the question, and Bacula will run without using block positioning, and it should recover your files.
SCSI tapes may either be written in variable or fixed block sizes. Newer drives support both modes, but some drives such as the QIC devices always use fixed block sizes. Bacula attempts to fill and write complete blocks (default 65K), so that in normal mode (variable block size), Bacula will always write blocks of the same size except the last block of a Job. If Bacula is configured to write fixed block sizes, it will pad the last block of the Job to the correct size. Bacula expects variable tape block size drives to behave as follows: Each write to the drive results in a single record being written to the tape. Each read returns a single record. If you request less bytes than are in the record, only those number of bytes will be returned, but the entire logical record will have been read (the next read will retrieve the next record). Thus data from a single write is always returned in a single read, and sequentially written records are returned by sequential reads.
Bacula expects fixed block size tape drives to behave as follows: If a write length is greater than the physical block size of the drive, the write will be written as two blocks each of the fixed physical size. This single write may become multiple physical records on the tape. (This is not a good situation). According to the documentation, one may never write an amount of data that is not the exact multiple of the blocksize (it is not specified if an error occurs or if the the last record is padded). When reading, it is my understanding that each read request reads one physical record from the tape. Due to the complications of fixed block size tape drives, you should avoid them if possible with Bacula, or you must be ABSOLUTELY certain that you use fixed block sizes within Bacula that correspond to the physical block size of the tape drive. This will ensure that Bacula has a one to one correspondence between what it writes and the physical record on the tape.
Please note that Bacula will not function correctly if it writes a block and that block is split into two or more physical records on the tape. Bacula assumes that each write causes a single record to be written, and that it can sequentially recover each of the blocks it has written by using the same number of sequential reads as it had written.
Linux does support both SCSI SPACE Filemarks and End-of-data: When MTEOM is called in MT_ST_FAST_MTEOM mode, SCSI SPACE End-of-data is used. In the other case, SCSI SPACE Filemarks with count = 8388607 is used. There is no real slow mode like in Solaris - I just expect, that for older tape drives Filemarks may be slower than End-of-data, but not so much as in Solaris slow mode. File number is tracked for MTEOM just without MT_ST_FAST_MTEOM - when MT_ST_FAST_MTEOM is used, it is not.
FreeBSD does support both SCSI SPACE Filemarks and End-of-data, but when MTEOD (MTEOM) is called, SCSI SPACE End-of-data is always used. FreeBSD never use SCSI SPACE Filemarks for MTEOD. File number is never tracked for MTEOD.
If I use Yes, OS must not use SCSI SPACE End-of-data, because Bacula expects, that there is tracked file number, which is not supported by SCSI specification. Instead, the OS have to use SCSI SPACE Filemarks.
If I use No, an action depends on Fast Forward Space File.
When I set Hardware End of Medium = no and Fast Forward Space File = no file positioning was very slow on my LTO-3 (about ten to 100 minutes), but
with Hardware End of Medium = no and Fast Forward Space File = yes, the time is ten to 100 times faster (about one to two minutes).
If you are not getting good performance, consider some of the following suggestions from the Allen Balck on the Bacula Users email list:
See if /var/adm/messages (or /var/log/messages) tells you what the sync rate of the SCSI devices/bus are. Also, the next time you reboot, the BIOS may be able to tell you what the rate of each device is.
If you are getting errors such as:
3992 Bad autochanger "load slot 1, drive 1": ERR=Child exited with code 1.
and you are running your Storage daemon as non-root, then most likely you are having permissions problems with the control channel. Running as root, set permissions on /dev/sgX so that the userid and group of your Storage daemon can access the device. You need to ensure that you all access to the proper control device, and if you don't have any SCSI disk drives (including SATA drives), you might want to change the permissions on /dev/sg*.
If you are getting errors such as:
: kernel: st0: MTSETDRVBUFFER only allowed for root
you are most likely running your Storage daemon as non-root, and Bacula is attempting to set the correct OS buffering to correspond to your Device resource. Most OSes allow only root to issue this ioctl command. In general, the message can be ignored providing you are sure that your OS parameters are properly configured as described earlier in this manual. If you are running your Storage daemon as root, you should not be getting these system log messages, and if you are, something is probably wrong.